View cart
Labconco 4" Biosafety Cabinet Delta Series Class II
Manufacturer: Labconco
Model: ALT-LABBSC4"
Purifier
® Delta® Series ClassII, Type A2 Safety Cabinets
Safety color-coded towel catch,*
surface, prevents wipes from being drawn into the blower where they
could damage components and alter airflow.
located beneath the work
99.99% efficient HEPA filters
replacement.
are industry standard sizes for economical
Curved stainless steel
air foil*
the user’s forearms without
the need for a separate
armrest. The radiused edge
prevents the potentially
dangerous practice of placing
materials in this area.
Contact Labconco at 800-
821-5525 or 816-333-8811
for ordering information on
an optional bold orange
epoxy coating to caution
operators to avoid storing
or placing materials near the
air foil.
gently supports
Reserve-Air
should the operator inadvertently block the air foil’s grille area. Safe
airflow is always maintained.
™ Secondary Airflow Slots* draw air into the cabinet
ADA-compliant fluorescent light and blower switches.
ADA-compliant sash position alarm
is raised above its 8" or 10" operating height. The alarm system may
be easily muted or reset from the control panel switch.
is activated when the sash
Two ADA-compliant electrical duplex receptacles,
on each side, with ground fault interruption and splash covers.
located one
Unitized,16 gauge stainless steel frame
and accurate foundation than multi-piece designs so the potential for
leaks is minimized.
provides a more stable
Variable speed blower
power consumption.
with solid state control is sized for low
Intrinsically-safe negative pressure design.
ducts are under negative pressure. The negative pressure plenums
capture any contamination, and force the air through the HEPA filter,
preventing its escape into the laboratory.
All contaminated
Fully-closing, clear 1/4" tempered safety glass sash
anti-racking mechanism is sloped at 10° for less glare and closer,
more comfortable viewing than vertical sashes offer. For easy loading
and cleaning, the sash may be raised to a maximum height of 18".
with
Tactile indication when sash is raised to optimum
operating level.
verification of the proper working height.
A sash position indicator decal provides a visual
Leak-tight Type 304 stainless steel liner and removable
stamped, one-piece dished work surface.
Air-Wave
side posts, air foil and sash handle, ensures smooth airflow into the
interior minimizing turbulence and enhancing containment.
™ Entry System,* consisting of the curved design of the
Contain-Air
preventing loss of containment at the top of the sash. Unreliable seals
and gaskets, which could degrade or drag on the contaminated glass
creating aerosols, are not used.
™Negative Pressure Channel* draws air in,
Low profile front panel
with visibility or obstruct taller users.
is free of protrusions that could interfere
Glare-free fluorescent lighting,
remains uncontaminated and is easily replaced.
located outside the work area,
Full three year warranty on parts and service.
NSF International and ETL listed.
Delta Series Safety Cabinets carry the NSF International and ETL marks,
signifying that the Purifier meets or exceeds all minimum requirements
of the NSF Standard 49 for Biohazard Cabinetry, conforms to UL Standard
3101-1/61010-1 in the U.S., and is certified to CAN/CSA C22.2
No. 1010.1-92 in Canada.
All 115 volt, 60 Hz, Purifier
CE mark.
(European Community) requirements as tested by the Inchcape Testing
Services (UK) LTD: Electrical Safety Standard: IEC 1010-1 and
Electromagnetic Compatibility Directive: 89/336/EEC.
All 230 volt, 50 Hz Purifiers conform to the following CE
Optional 254 nm UV lamp
the cabinet is not in use. Interlocked switch permits the UV light to
operate only when the fluorescent light and blower are off and the
sash is completely closed.
for secondary decontamination while
Optional ADA-compliant service fixtures
the work surface to maximize usable surface area. Service fixtures are
available factory-installed or may be ordered separately.
are mounted 9" above
Optional audible/visual low velocity alarm indicator
monitors the volume of air exhausted from the cabinet. Should
the exhaust (inflow) volume drop below the setpoint, the red warning
light is activated. Contact Labconco at 800-821-5525, 816-333-8811
or labconco@labconco.com for more information.
continuously
Accessory Base Stands.
are benchtop design for use on existing casework or NSF-Listed
Labconco Telescoping, Hydraulic Lift, Solo, Unassembled and
Seismic Base Stands.
Purifier Delta Series Safety Cabinets
Exclusive feature
* U.S. Patent No. 6,368,206
Purifier
® Delta® Series ClassII, Type A2 Safety Cabinets
Standard Features
•
U.S. Patent No. 6,368,206
•
Nominal inflow velocity of 105 feet per minute (fpm)
•
Nominal downflow velocity of 55 fpm
•
Approximately 70% air recirculation
•
Intrinsically-safe negative pressure design
•
Two 99.99% efficient HEPA filters
•
Unitized 16 gauge stainless steel substructure
•
seamless, dished work surface
Crevice-free, type 304 stainless steel interior and removable,
•
Glacier white epoxy-coated exterior
•
and perforated exhaust filter cap
Safety color-coded and epoxy-coated steel towel catch, sash pocket
•
with anti-racking mechanism, tactile position indicator and 18"
maximum loading height
10° angled, sliding, fully-closing, 1/4" tempered safety glass sash
•
Air-Wave™ Entry System
•
Stainless steel air foil with Reserve-Air™ Secondary Airflow Slots
•
Contain-Air™ Negative Pressure Channel
•
ADA-compliant, eye-level, inside-mounted pressure gauge
•
ADA-compliant fluorescent light and blower switches
•
ADA-compliant audible/visual alarm indicator with mute switch
•
interrupters and splash covers
Two ADA-compliant electrical duplex receptacles with ground fault
•
10' power cord
•
capacity
Sure-Start™ voltage-compensating speed control with 40 amp
•
Thermally-protected permanent split capacitor motor/blower(s)
•
Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
•
No. 1010.1 conformity (115 volt models)
NSF and ETL Listed, UL 3101-1/61010-1 and CAN/CSA C22.2
•
CE conformity marking (230 volt models)
•
EN 12469 approved (Models 3620930 and 3620934)
•
Three year warranty on parts and service
Standard Option Package
•
only when blower and fluorescent light are off and sash is fully
closed
254 nm UV lamp with interlocking safety switch allowing operation
•
handle, factory installed 9" above work surface
Chrome-plated forged brass service fixture(s) with quarter turn
Required Accessory
•
Supporting base. Place on existing casework or see pages 60-65.
See page 26 for dimensional drawings.
Exclusive feature
Purifier Delta Series Class II, Type A2 Safety Cabinet 3620004 on SoLo Hydraulic Lift
Base Stand 3780312.
Installation Requirements
Location.
ventilation registers and other air handling devices.
Locate the cabinet away from traffic patterns, doors, fans,
Electrical.
circuit breaker with current capacity equal to or greater than the
electrical requirements provided in the ordering information.
The cabinet requires a dedicated electrical receptacle and
Services.
equipped with an easily accessible shut-off valve located outside
the cabinet. Line pressure should not exceed 40 psi.
All service lines must be 1/4" OD metal tubing and
Space.
cabinet is recommended.
Clearance of at least 6 inches on the sides and rear of the
Overhead Clearance.
least 6 inches clearance between the top of the exhaust cover and
the ceiling.
Class II, Type A2 cabinets should have at
Certification.
a qualified certifier. Under normal operating conditions, the cabinet
should be recertified at least annually, and when moved or serviced.
Prior to initial use, the cabinet must be certified by
F E A T U R E S & B E N E F I T S
ADA-compliant, eye-level Minihelic II pressure gauge*
is mounted inside the cabinet instead of externally so that should a
leak develop from the gauge or tubing, contaminants would be HEPA
filtered instead of being released into the laboratory.