View cart
- New Equipment
- Bactron Chambers
- Biosafety Cabinets
- Fume Hoods
- Basic Laboratory Fume Hoods
- Canopy Hoods
- Fiberglass 30 Laboratory Hoods
- Protector ClassMate Laboratory Hoods
- Protector Demonstration Hood
- Protector Pass-Through Laboratory Hoods
- Protector Premier Laboratory Hoods
- Protector PVC Perchloric Acid and Acid Digestion Laboratory Hoods
- Protector Stainless Steel Perchloric Acid Laboratory Hoods
- Protector Stainless Steel Radioisotope Laboratory Hoods
- Protector Work Stations without Blower
- Protector XL Benctop Laboratory Hoods
- Protector XL Floor-Mounted Laboratory Hoods
- Protector XLE Laboratory Hoods
- Protector XStream Laboratory Hoods
- Protector XVS Ventilation Stations
- Humidity Cabinets
- SHEL LAB Incubators
- Lab Ovens
- Laboratory Refrigerators
- Laboratory Freezers
- Water Baths
- Incubator Shaker
- Freeze Dry Systems
- Laboratory Glassware Washers
- Vacuum Ovens
- Water Purification Systems
- Wireless Temperature Monitoring Systems
- Used Equipment
- Parts
Labconco Protector Stainless Steel Radioisotope Laboratory Hoods
Manufacturer: Labconco
Model: 4882200
Protector Stainless Steel Radioisotope Laboratory Hoods provide protection from applications requiring the use of radiochemicals. They feature fully sealed integral work surfaces and coved interiors to facilitate decontamination.
Available in 4, 5, 6 and 8-foot widths, these benchtop hoods feature a corrosion-resistant Type 304 stainless steel interior. The one-piece liner is free of joints, cracks or crevices to prevent build-up of residue and simplify decontamination procedures.
Features
• By-pass airflow design
• Curved air foil allows air to sweep the work surface while Clean-Sweep™ openings pull inflow air from under the air foil.
• Glacier white, dry powder epoxy-coated steel exterior
• Seamless Type 304 stainless steel liner with integral work surface
• Black enamel-coated hardboard surface to support the integral work surface
• 3/16" thick tempered safety glass vertical-rising sash with frame of epoxy-coated aluminum and PVC
• Removable front and side panels and front access panels for access to plumbing and electrical wiring
• Energy-efficient T8 fluorescent lighting,
• Light switch and blower switch for 115 volt, 60 Hz operation pre-wired to a single point internal junction box
• Two pre-plumbed service fixtures with forged brass valves and chrome-plated brass serrated hose connectors, lower right side with brass tubing for gas and lower left side with copper tubing for air
• Pre-wired 115 volt electrical duplex receptacle on lower right side
• 11" OD Type 304 stainless steel exhaust connection(s)
Compliance
• SEFA 1-2002 (Laboratory Fume Hoods)
• NFPA 45-2000 (Fire Protection for Laboratories Using Chemicals) section 6-1 through 6-14
• ASTM E84-01 Surface Burning Characteristics of Building Materials
• ASHRAE 110-95 (Method of Testing Performance of Laboratory Fume Hoods)
• ANSI Z9.5-1993 (Laboratory Ventilation)
• UL 3101-1/61010-1
• CAN/CSA Standard C22.2 No. 1010.1
• UL 1805
Specifications
| No specs listed |
HOURS
M - F: 7AM to 5PM (PST)
TELEPHONE
866-LAB-FIXX (866-522-3499)
FAX
408-245-3866
SHIPPING ADDRESS
823 Kifer Rd.
Sunnyvale, CA 94086