View cart
- New Equipment
- Bactron Chambers
- Biosafety Cabinets
- Fume Hoods
- Basic Laboratory Fume Hoods
- Canopy Hoods
- Fiberglass 30 Laboratory Hoods
- Protector ClassMate Laboratory Hoods
- Protector Demonstration Hood
- Protector Pass-Through Laboratory Hoods
- Protector Premier Laboratory Hoods
- Protector PVC Perchloric Acid and Acid Digestion Laboratory Hoods
- Protector Stainless Steel Perchloric Acid Laboratory Hoods
- Protector Stainless Steel Radioisotope Laboratory Hoods
- Protector Work Stations without Blower
- Protector XL Benctop Laboratory Hoods
- Protector XL Floor-Mounted Laboratory Hoods
- Protector XLE Laboratory Hoods
- Protector XStream Laboratory Hoods
- Protector XVS Ventilation Stations
- Humidity Cabinets
- SHEL LAB Incubators
- Lab Ovens
- Laboratory Refrigerators
- Laboratory Freezers
- Water Baths
- Incubator Shaker
- Freeze Dry Systems
- Laboratory Glassware Washers
- Vacuum Ovens
- Water Purification Systems
- Wireless Temperature Monitoring Systems
- Used Equipment
- Parts
Labconco Protector XL Benchtop Laboratory Hoods
Manufacturer: Labconco
Model: 9750400
The Protector XL Benchtop Laboratory Hoods offer superior design flexibility. Their panel liners may be constructed of a variety of corrosion-resistant materials and are supplied in three depths to meet individual installation and application requirements. Protector XL Benchtop Laboratory Hoods are suitable for general chemistry applications.
Features
• By-pass airflow design
• Curved air foil allows air to sweep the work surface while Clean-Sweep™ openings pull inflow air from under the air foil.
• Glacier white, dry powder epoxy-coated steel exterior
• Chemical-resistant molded composite panel liner and pre-set baffle(s) with flame spread less than 25 per ASTM E-84
• 3/16" thick tempered safety glass vertical-rising sash(es) with epoxy-coated aluminum frame(s)
• Removable front and side panels and front and interior access panels for access to plumbing and electrical wiring
• Pre-wired instant-start T8 fluorescent lighting, ADA-compliant light and blower switches
• Epoxy-coated, stainless steel 12.81" ID exhaust connection(s)
• Factory prepared for eight ADA-compliant service fixtures including two gooseneck faucets
• Factory prepared for up to four electrical duplex receptacles
• ETL listed
Compliance
• SEFA 1-2002 (Laboratory Fume Hoods)
• NFPA 45-2000 (Fire Protection for Laboratories Using Chemicals) section 6-1 through 6-14
• ASTM E84-01 Surface Burning Characteristics of Building Materials
• ASHRAE 110-95 (Method of Testing Performance of Laboratory Fume Hoods)
• ANSI Z9.5-1993 (Laboratory Ventilation)
• UL 3101-1/61010-1
• CAN/CSA C22.2 No. 1010.1
• UL 1805
Specifications
| No specs listed |