View cart
- New Equipment
- Bactron Chambers
- Biosafety Cabinets
- Fume Hoods
- Basic Laboratory Fume Hoods
- Canopy Hoods
- Fiberglass 30 Laboratory Hoods
- Protector ClassMate Laboratory Hoods
- Protector Demonstration Hood
- Protector Pass-Through Laboratory Hoods
- Protector Premier Laboratory Hoods
- Protector PVC Perchloric Acid and Acid Digestion Laboratory Hoods
- Protector Stainless Steel Perchloric Acid Laboratory Hoods
- Protector Stainless Steel Radioisotope Laboratory Hoods
- Protector Work Stations without Blower
- Protector XL Benctop Laboratory Hoods
- Protector XL Floor-Mounted Laboratory Hoods
- Protector XLE Laboratory Hoods
- Protector XStream Laboratory Hoods
- Protector XVS Ventilation Stations
- Humidity Cabinets
- SHEL LAB Incubators
- Lab Ovens
- Laboratory Refrigerators
- Laboratory Freezers
- Water Baths
- Incubator Shaker
- Freeze Dry Systems
- Laboratory Glassware Washers
- Vacuum Ovens
- Water Purification Systems
- Wireless Temperature Monitoring Systems
- Used Equipment
- Parts
Labconco Protector XL Floor-Mounted Laboratory Hoods
Manufacturer: Labconco
Model: 9860401
Protector XL Floor-Mounted (Walk-In) Laboratory Hoods have panel liners that may be constructed of a variety of corrosion-resistant materials and supplied in three depths to meet individual installation and application requirements.
They are suitable for general chemistry applications and accommodate oversized apparatus. Widths of up to 16 feet are offered.
Features
• By-pass airflow design
• Dry powder, glacier white epoxy-coated steel exterior
• Chemical-resistant molded composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84
• Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring
• Pre-wired instant-start T8 fluorescent lighting, light and blower switches for 115 volt, 60 Hz operation
• Two 3/16" thick tempered safety glass vertical-rising sashes framed with PVC (4', 5' and 6' models) or epoxy-coated aluminum (8' models)
• Four 3/16" thick tempered safety glass horizontal-sliding sashes with epoxy-coated aluminum frames and sash tracks (8', 10', 12', 16' models)
• Factory prepared for up to eight service fixtures including two gooseneck faucets
• Factory prepared for up to four electrical duplex receptacles
• Shipped in multiple sections, top and bottom
• Epoxy-coated, stainless steel 12.81" ID exhaust connection(s)
• ETL listed
Compliance
• SEFA 1-2002 (Laboratory Fume Hoods)
• NFPA 45-2000 (Fire Protection for Laboratories Using Chemicals) section 6-1 through 6-14
• ASTM E84-01 Surface Burning Characteristics of Building Materials
• ASHRAE 110-95 (Method of Testing Performance of Laboratory Fume Hoods)
• ANSI Z9.5-1993 (Laboratory Ventilation)
• UL 3101-1/61010-1
• CAN/CSA C22.2 No. 1010.1
• UL 1805